UEW6DHG DC Disconnectors

  • Product Name: DC Disconnectors
  • Poles Description: 2
  • Line Rated Current: 800A、1000A、1250A、1600A、2000A、2500A
  • Rated Operational Voltage[Ue]: DC1500V
  • Selectivity Category: DC-PV2
  • Mounting Mode: Fixed
INQUIRY

Overview

Kemus is a leading provider of electrical switchgear and electronic components. Our products include circuit breakers, surge protectors, disconnect switches, contactors, relays, and indicators for voltage and fault detection.

Kemus insists on a comprehensive quality assurance system, ensuring our products meet global standards for safety and reliability.

Product Description

UEW6DHG DC Disconnectors

UEW6DHG-2500 2P is suitable for rated DC1500V, rated current 800A ~2500A distribution network, with load isolation function, the product is widely used in photovoltaic power generation, energy storage, data center and other DC distribution system.

Kemus DC Disconnectors switches Product Characteristics:

– Low temperature rise: The DC Disconnectors ambient temperature is up to 55 °C without derating

– Unipolar critical load current: DC Disconnectors Unipolar critical load current up to 1500V

– Short arc: DC Disconnectors greatly improve safety and save space in the cabinet

– DC Disconnectors Small size: 70% size of similar products

– Module: Modular design, expandable to AC 3-pole and 4-pole switches

– Eco-friendly: The DC Disconnectors is fully RoHS 2.0 compliant

UEW6DHG DC Disconnectors structure:

1.Interphase Barriers        2.Terminal Busbar      3. TerminalsBlock        4. OFF Button (0)
5. ON Button (I)              6.Charging Handle         7.Charged\Discharged Indicator
8.Close (I) \Open(O) Indicator           9.Counter Window             10.Side Panel

DC disconnecting switch Advantages

The advantages of using DC switch include:

Safety: UEW6DHG DC Disconnectors provide a safe way to isolate the DC power source, reducing the risk of electric shock during maintenance or in case of faults.

Reliability: Disconnectors are designed to withstand high voltages and currents, ensuring reliable operation in various applications.

Ease of Use: Disconnecting switch often feature a simple on/off mechanism, making them easy to operate.

Versatility: Disconnectors can be used in a wide range of applications, from small-scale systems to large industrial setups.

Protection: Some models offer built-in protection features such as overcurrent and short-circuit protection.

DC Disconnectors Technical Parameters
  • Product Name: DC Switch disconnecting
  • Product or Component Type: Switch disconnecting
  • Device Application: Power distribution protection
  • Poles Description: 2
  • Line Rated Current: 800A、1000A、1250A、1600A、2000A、2500A
  • Rated Operational Voltage[Ue]: DC1500V
  • Selectivity Category: DC-PV2
  • Mounting Mode: Fixed
DC Disconnectors Complementary Parameters
  • Rated Short-Time Withstand Current [Icw]: DC1500V 50 kA/1s
  • Rated Short-Circuit Making Capacity[Icm]: DC1500V 50 kA/1s
  • Rated Insulation Voltage [Ui]: DC1600V
  • Rated Impulse Withstand Voltage [Uimp]: 12 kV
  • Maximum Breaking Time: <30 ms(<63A)
  • Maximum Closing Response Time: 70 ms
  • Connection Pitch: 135mm
  • Mechanical Durability: 10000 Without maintenance

Why Choose Kemus

20 +
Years Experience
50 +
Export Countries
300 +
Projects
1000 +
Customers

Kemus DC Disconnectors Practical Plant Capacity

Kemus DC Disconnectors Application Fields

DC Disconnectors Compatible Accessories

  • 1. Auxiliary Contact - Conventional Thermal Current: 16A - Nominal Insulation Voltage: 400V
  • 2. Electric Operating Mechanism - Operating Threshold: (0.85...1.1) Ue - Rated Power: 110W
  • 3. No-voltage Release - Operating Voltage: (0.35...0.7)Ue - Reliable Closing Voltage:(0.85...1.1)Ue - Reliable Non-Closing Voltage:≤0.35 Ue
  • 4. Opening Lock Tunction: The switch is locked in the opened position and it is guaranteed the switch can not close.
  • 5. Shunt Release - Tripping Time No more than 30ms
  • 6. Undervoltage Trip Device - Time of Delay: Instantaneous、1s、3s、5s
  • 7. Closing electromagnetic - Closing Time: No more than 70ms
  • 8. Interphase barrier Functions: It is installed between each phase busbar to increase the insulation strength between each phase and prevent short circuit between busbars.

Kemus Power Technology Cooperative Brand

DC Disconnectors Receiving Inspection

Check the received goods and verify whether the model, specification and quantity DC switch disconnector (hereinafter referred to as disconnector) are the same as the ordered goods. When opening the wooden packing box for inspection, avoid bruising the disconnector and damaging the package. It is recommended to keep the wooden packing box until installation and use. After carrying out an inspection of the goods received, even if it will be installed and used in a short time, please still put the disconnector back into the package, taking care to protect it from water and moisture. If any damage or abnormality is found during the inspection, please contact us within 5 days after receiving the goods.

  • The storage environment shall be dry, dust-free, and free from corrosive and explosive chemicals.
  • Please place the disconnector horizontally on any fixed parts, no directly on the ground.
  • During storage and transport, the disconnector shall be in disconnected state and the spring mechanism in the energy release state.
  • During moving for installation, take care to protect the disconnector and personnel; Tipping, hitting or dropping may lead to damage to the disconnector.
  • Electric energy storage: When the disconnector releases energy, if the electric energy storage mechanism is energized, the energy storage motor will automatically store energy to the disconnector operating mechanism, and the motor will stop automatically when the energy storage is finished, and a clicking sound can be heard, at this time the panel "energy storage/release" indication is in the storage state.
  • Underclosingstatus, press the opening button on the panel or energize the shunt release to hear the "bell" sound. At this time, the "I / O" indication window on the panel indicatesas"O", meaning that the disconnector has been disconnected. At this time, the energy release of the disconnector operating mechanism is completed.
  • Manual energy storage: similarly, the manual energy storage handle can be pressed to store energy; Press down for about 6 or 7 times, hear a click, and the reaction force of pressing down the handle decreases obviously. At this time, the "energy storage / energy release" indication on the panel is in the energy storage state, indicating that the energy storage is completed.
  • In the case of energy storage, press the closing button or energize the closing electromagnetic iron, and you will hear the "bell" sound. At this time, the "I / O" indication window on the panel indicates as"I", meaningthat the disconnector has been closed. At the same time, the "energy storage / release" indication on the panel is in the energy release state. At this time, if the energy storage mechanismis still powered on, the energy storage mechanism will automatically store energy for the operating mechanism of the disconnectoragain. After energy storage, the motor will stop automatically, and the "energy storage / release" indication on the panel isin the energy storage state.

Products Packing & Delivery

DC Disconnectors FAQ

  • What is Kemus DC Disconnector? Kemus DC Disconnect Switches are safety devices used in DC circuits, capable of quickly disconnecting or connecting the circuit to ensure safety during maintenance, testing, or emergencies.
  • How does Kemus ensure the quality of DC Disconnector? Kemus DC Disconnector has passed CCC, CB, TUV certification.
  • Can I get samples from your company? Yes, Samples can be provided.
  •  If products have some quality problem, how would you deal with? Our company will responsible for all the quality problems.
  • What is the customer you work with? We work with famous brands such as: Enel, SMA, JCI, GE, Honeywell, United Technologies, SGCC, Sinopec, China GuoDian, Power China, China Post, ZiJin Minning and so on.
  • What is the rated current of the line? 800A、1000A、1250A、1600A、2000A、2500A
  • How long is the disconnector warranty period? Kemus DC Disconnector warranty period is 2 years
  • What is your lead time? Normal within 10 days. It depends on detail items and quantity.
Get A Free Quote
Contact us for free quotes and more professional knowledge about product. We will prepare a professional solution for you.



    Leave Your Message

      * Name

      * Email

      Phone/WhatsAPP/WeChat

      Company

      * What I have to say