AFDD Arc Fault Detection Device

  • Product Name: Arc Fault Detection Device
  • Product Model: AFDD
  • Rated Voltage: 230V
  • Rated Current: 6A 10A 16A 26A
  • Poles: 1P+N
  • Rated Frequency: 50 Hz
  • Rated Short-Circuit Capacity: 6KA
  • Meeting Standards: GB/T 14048、IEC 60947
  • Certificates: CCC CE CB RoHS
INQUIRY

Overview

AFDD arc fault protection circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current to 20A and below the line, used for building and similar uses of the line for over-current protection, while can detect in advance due to electrical device rupture or wire aging caused by a lot of fire risk. Protection against ground arc faults, parallel arc faults and series arc faults. It can reduce the occurrence of fire safety accidents to a certain extent, and provide effective protection for people’s lives and property safety.

Kemus is a leading provider of electrical switchgear and electronic components. Kemus products include mini breaker, surge protectors, disconnect switches, contactors, relays, and indicators for voltage and fault detection.

Kemus insists on a comprehensive quality assurance system, ensuring our products meet global standards for safety and reliability.

Product Description

AFDD arc fault protection circuit breaker is composed of small circuit breaker and arc fault protection module, which has overload, short circuit, arc fault protection and other protection functions.

AFDD Arc Fault Detection Device has the following functions:

① Overload long delay protection;

② Overload short delay protection;

③ Instantaneous trip protection;

④ Series arc fault protection;

⑤ Parallel arc fault protection;

⑥ Ground arc fault protection;

⑦ A variety of current specifications.

The most prominent function of AFDD is that it can detect arc faults in the line and disconnect arc faults.
It is recommended for places where people are dense and flammable materials are concentrated, such as home improvement, schools, hotels, libraries, etc.

AFDD Arc Fault Detection Device Mounting Dimension:

 

Electrical products more information, such as product selection manual, product drawing,  welcome to contact us, look forward to win-win cooperation

Xiamen Kemus Power Technology Co., Ltd.
​Business Personnel: Belinda
​Email: ​belinda@kemusep.com
​Mob/Wechat/WhatsApp: 0086-15260358715

AFDD Arc Fault Detection Device Attachment Installation Diagram

AFDD Parts Name
  • ① AFDD
  • ② MVMN Over and Under voltage release, MSN No Voltage Release, MN undervoltage release and MV overvoltage release
  • ③ MO shunt release device, MOWY passive shunt release device
  • ④ FS auxiliary + alarm contact
  • ⑤ FF double auxiliary contacts
  • ⑥ Bus-bar
AFDD Assembly Instruction
  • (1) Accessories without tool installation, installation position on the left side of the circuit breaker.
  • (2) The total width of the accessories assembly within 54mm, from left to right sequence number: 0F/FF/FS/SD(3max.)+MO/MV/MN/MVMN/MSN/MOWY(2 max.)+AFDD.
  • (3) Accessories are commonly used in CDB9, CDB9LE, CDB9P, CDB9PLE, AFDDLE, etc

Why Choose Kemus

20 +
Years Experience
50 +
Export Countries
300 +
Projects
1000 +
Customers

Kemus Company Products Superiority

  • – High reliability: They responsible for protecting lines and equipment in the power system, which itself has high reliability and anti-interference, and can effectively protect the normal operation of the power system.

     

    – High flexibility: They can be adjusted and controlled according to actual needs, with high flexibility and operability, and can adapt to different power system needs.

     

    – Easy maintenance: If an electronic component fails, it can quickly replace the failed component;

     

    – Supply Ability: Our company spirit of “all the pursuit of high quality, customer satisfaction for the purpose”, to provide customers with the most favorable prices, the most thoughtful service and the most reliable product quality.

     

    – Original Country Technology: Our products incorporate cutting-edge technology sourced directly from the countries of origin, guaranteeing the latest advancements in electrical safety.

     

    – Quality Assurance: Every products our company provide has a 100% passing rate in quality checks, reflecting our commitment to excellence and reliability in every unit.

     

Application Fields

Kemus Power Technology Cooperative Brand

Cooperate with us, you will get

Kemus is a leading provider of electrical switchgear and electronic components. Our electronic products reflect our commitment to ensuring reliability and adherence to global safety standards, marked by certifications such as UL/CUL, VDE, COC, and CCC. Kemus insists on a comprehensive quality assurance system, ensuring our products meet global standards for safety and reliability.

  • Direct factory price
  • Quality quaranteed
  • Supply stability
  • Delivery on time
  • Thoughtful service
  • More options from us
  • Professional introduction and advice
  • Small size and weight, save space
  • Modular design reduces installation difficulty
  • Removable, replaceable, easy to maintain and repair
  • Reduce maintenance costs and time costs
  • Reduce power system losses
  • High flexibility and maneuverability
  • As technology advances, it is easy to upgrade

Products Packing & Delivery

Kemus Electrical Product FAQ

  • What is the customer you work with? We work with famous brands such as: Enel, SMA, JCI, GE, Honeywell, United Technologies, SGCC, Sinopec, China GuoDian, Power China, China Post, ZiJin Minning and so on.
  • How does Kemus ensure the quality? Kemus Products have passed CCC, CB, TUV, CQC, CE, UKCA certification.
  • Can I get samples from your company? Yes, Samples can be provided. International freight at your own expense.
  • How long is the AFDD warranty period? Kemus AFDD this products warranty period is 36 months.
  • What is your lead time? Normal within 10 days. It depends on detail items and quantity.
  • If products have some quality problem, how would you deal with? Our company will responsible for all the quality problems.
  • What is the most important function of AFDD? The most prominent function of AFDD is that it can detect arc faults in the line and disconnect arc faults. It is recommended for places where people are dense and flammable materials are concentrated, such as home improvement, schools, hotels, libraries, etc.
Get A Free Quote
Contact us for free quotes and more professional knowledge about product. We will prepare a professional solution for you.



    Leave Your Message

      * Name

      * Email

      Phone/WhatsAPP/WeChat

      Company

      * What I have to say